FIBRO - Standard Parts

J56 1 2 4 3 TRANSPORTER ELECTRICAL - ACCESSORIES SIGNAL CABLE STRAIGHT, TO THE PRESS Description: The signal cable connects the control unit to the power press/production machine. 2299.60.81.01. Signal cable straight, to the press Order No l [m] 2299.60.81.01.03 3 2299.60.81.01.05 5 2299.60.81.01.10 10 M12 - Plug 4-pin / A-coded 1 (brown) = Start/stop Digital input 24 V DC = Start 2 (white) = Fault Digital output 24 V DC = Fault 3 (blue) = 0 V DC Together 0 V DC = 0 V 4 (black) = Control unit Digital output 24 V DC = OK Output Conditions Pin 2 Pin 4 Fault 24 V / (+) 24 V* 0 V OK 0 V 24 V / (+) 24 V* Input Conditions Pin 1 Pin 3 started 24 V / (+) 24 V* -0 V stopped 0 V -0 V *for control unit with potential-free output Assignment:

RkJQdWJsaXNoZXIy MTIwNzY0